Range : 0.5 A to 400.0 A
Resolution : 0.1 A
Accuracy
• 400.0 A: 2 % ± 5 digits (10 Hz to 100 Hz), 2.5 % ± 5 digits
• (100 Hz to 500 Hz)
Inrush : Max displayed reading: 999.9A
Crest factor (50 Hz/60 Hz)
• 3 at 500 A, 2.5 at 600 A, 1.42 at 1000 A, add 2 % for C.F. > 2
LCD w/backlight : 3½ digits
Log rate/interval : 1 sec minimum/adjustable by PC
Battery type : 2 AA, NEDA 15 A, IEC LR6
Battery life : 400 hours
Memory : Record up to 65,000 readings
RF communications : 2.4 GHZ ISM Band
RF communication range
• Open air, unobstructed: Up to 20 m
• Obstructed, sheetrock wall: Up to 6.5 m
• Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Operating temperature : -10 °C to +50 °C
Storage temperature : -40 °C to +60 °C
Temperature coefficient
• Add 0.1 x (specified accuracy)/°C (< 18 °C or > 28 °C)
Operating humidity
• 90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
Altitude
• Operating: 2,000 m
• Storage: 12,000 m
EMC : EN 61326-1:2013
Safety compliance : IEC 61010-1, CAT III 600 V, CAT IV 300 V, 3rd edition
Safety rating : CAT III 600 V, CAT IV 300 V
Certifications : cCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating : IP30
Pollution Degree : 2
Jaw opening : 34 mm (1.33 in)
Size (HxWxD) : 20.3x7.49x3.55 cm (8x2.95x1.4 in)
Weight : 0.22 kg (8 oz)