Maximum voltage between
terminal and earth ground
(meter) : 30 V dc or ac rms
LCD w/backlight : 3 ½ digits, 6000 counts, 4/sec update rate
Log rate/Interval : Adjustable by PC from 1 sec to 1 hr, default 1 min
Battery type : 2 AA Alkaline batteries, NEDA 15A, IEC LR6
Battery life : 400 hours minimum
Memory : Record up to 65,000 readings
RF communications : 2.4 GHz ISM Band
RF communication range
• Open air, unobstructed: Up to 20 m
• Obstructed, sheetrock wall: Up to 6.5 m
• Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Operating temperature : -10 °C to +50 °C
Storage temperature : -40 °C to +60 °C
Temperature coefficient : 0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C)
Relative humidity
• 0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C),
• 0 % to 45 % (40 °C to 50 °C)
EMC
• IEC 61236-1:2013
• Protected to IEC 61010-1, 3rd edition, Pollution Degree 2
Certifications : cCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating : IP42
Size (HxWxD) : 160x66x38 mm (6.3x2.6x1.5 in)
Weight 0.255 kg (9 oz)