Range
• 1.0 A to 999.9 A dc, 1000 A to 2000 A dc
Resolution : 0.1 A, 1 A
Accuracy : 2 % ± 5 digits, 2.5 % ± 5 digits
LCD w/backlight : 3½ digits
Log rate/interval
• 1 sec minimum/adjustable by PC or front panel
Battery type
• 2 AA, NEDA 15 A, IEC LR6
Battery life : 120 hours
Memory : Record up to 65,000 readings
RF communications : 2.4 GHZ ISM Band
RF communication range
• Open air, unobstructed (up to 20 m)
Operating temperature
• Obstructed, sheetrock wall (up to 6.5 m)
• Obstructed, concrete wall or steel electrical enclosure (up to 3.5 m)
• -10 °C to +50 °C
Storage temperature : -40 °C to +60 °C
Temperature coefficient
• Add 0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C)
Operating humidity
• 90 % at 35 °C
• 75 % at 40 °C
• 45 % at 50 °C
Altitude
• Operating: 2,000 m
• Storage: 12,000 m
EMC : EN 61326-1:2013
Safety compliance
• IEC 61010-1, CAT IV 600 V, CAT III 1000 V, 3rd edition
Safety rating : CAT IV 600 V, CAT III 1000 V
Certifications : cCSAus, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating : IP42
Jaw opening : 64mm
Size (HxWxD) : 16.5x6.35x1.4 cm (6.5x2.5x1.4 in)
Weight : 0.65 kg (1.75 lb)